Lever, Counter Weight Operated Limit SwitchesIntroductionLawa Lever < and weight operated ) type Limit Switch LLS / CWLS operates the control change-over Contacts of motor ot an moving equipment when a Cam moving with loads actuates the Lever ol limit switch. This turns the cams tin a square shall and operates I he NO / NC contact elements.
OperationTwo or more Contact Elements are operated by respective rotating Cams, which are suitably fixed on a square Cam Shaft turned by a lever or weight. The contacts operate at 14 from central neutral position.
DesignThe Sheet Steel hody, lever and Cover of the Limit Switch are finished by powder roating treatment. The Cam Shaft is mounted in the housing on moulded Nylon bushes ( bearing) and are fixed through the front & rear walls.
Technical Data:
- Body material Degree ot protection Mounting position Cable entries No. of contact Wire connection Rated voltage Tliermal test current
- Powder coated sheet IP-41
- Floor mounting Twin. 3/4' BS conduit 213 /or 4 Silver-cadmimum 500 Vac 10 A
- Operating Executions:
- The operating mechanism can be offered in two executions:
- I. Roller Operating A lever :
- These Limit Switches are used tor E.O.T. Cranes. Wagon Shunting devices. Elevators. Travel mechanism or such linearly moving mechanisms to prevent over-travel. The position ol operating lever is in up / down, and can be changed in steps ot 90 at site.